Technical Parameters of the Device
| Sample weight | up to 3 kg |
| Air heater power | 6.6 kW |
| Ultrasonic frequency | 26 kHz |
| Material weight measurement accuracy | 0.01 g |
| Microwave power | 200 W |
| Measured parameters | velocity and temperature of inlet air, humidity of inlet and outlet air, sample temperature |
| Adjustable parameters | velocity and temperature of inlet air |
| Data logging and export from the program | spreadsheet |
Description
The device is equipped with an ultrasonic transducer that generates a wave with a frequency of approximately 26 kHz. A novel method of measuring the mass of the material rotating in the drum is used, involving pneumatic disengagement of the drive.
Gallery